;ษอออออออออออออออออออออออออออออออออออออออออออออออออออออออออออออออออป ;บ บ ;บ Olicom 32 Bit EISA 16/4 Token-Ring Network Adapter บ ;บ Adapter Configuration File Version 1.03 บ ;บ (C) Copyright 1992 Olicom A/S บ ;บ บ ;ศอออออออออออออออออออออออออออออออออออออออออออออออออออออออออออออออออผ BOARD ID = "OLC1201" NAME = "Olicom 32 Bit EISA 16/4 Token-Ring Network Adapter" MFR = "Olicom" CATEGORY = "NET" SLOT = EISA LENGTH = 240 AMPERAGE = 2000 SKIRT = NO READID = YES IOCHECK = INVALID DISABLE = UNSUPPORTED COMMENTS = "\nThis is the Olicom 32 Bit EISA 16/4 dual-speed (16 Mbps or 4 Mbps) Token-Ring Network adapter card for EISA bus computers.\n All configuration of the adapter is software setable using this setup utility. There are no additional jumpers or switches." IOPORT(1) = 0zC20h ; Configuration Register 00h INITVAL = 00000000b IOPORT(2) = 0zC21h ; Configuration Register 01h INITVAL = 00xxxxxxb IOPORT(3) = 0zC22h ; Configuration Register 02h INITVAL = 00000000b IOPORT(4) = 0zC23h ; Configuration Register 03h INITVAL = xxxxxxxxb FUNCTION = "Token-Ring Network Adapter" TYPE = "NET,TOK" SUBFUNCTION = "I/O Address Location" COMMENTS = "\nUp to eight Olicom Token-Ring Network adapters may be installed in this computer. An adapter must use one of eight I/O port address combinations. Each combination consists of two I/O address ranges. The selections are, in order of preference:" CHOICE = "0 = 0A18-0A23 & 0A30-0A3F" LINK PORT = 0A18h-0A1Fh SHARE = NO SIZE = DWORD PORT = 0A20h-0A23h SHARE = NO SIZE = DWORD PORT = 0A30h-0A3Fh SHARE = NO SIZE = WORD INIT = IOPORT(4) LOC(7 2 1) 000 INIT = PORTADR(0A38h) 10000000 INIT = PORTADR(0A38h) 01100000 INIT = PORTADR(0A39h) 00000000 CHOICE = "1 = 0A24-0A2F & 0A40-0A4F" LINK PORT = 0A28h-0A2Fh SHARE = NO SIZE = DWORD PORT = 0A24h-0A27h SHARE = NO SIZE = DWORD PORT = 0A40h-0A4Fh SHARE = NO SIZE = WORD INIT = IOPORT(4) LOC(7 2 1) 001 INIT = PORTADR(0A48h) 10000000 INIT = PORTADR(0A48h) 01100000 INIT = PORTADR(0A49h) 00000000 CHOICE = "2 = 0A50-0A53 & 0A58-0A6F" LINK PORT = 0A58h-0A5Fh SHARE = NO SIZE = DWORD PORT = 0A50h-0A53h SHARE = NO SIZE = DWORD PORT = 0A60h-0A6Fh SHARE = NO SIZE = WORD INIT = IOPORT(4) LOC(7 2 1) 010 INIT = PORTADR(0A68h) 10000000 INIT = PORTADR(0A68h) 01100000 INIT = PORTADR(0A69h) 00000000 CHOICE = "3 = 0A54-0A57 & 0A70-0A87" LINK PORT = 0A80h-0A87h SHARE = NO SIZE = DWORD PORT = 0A54h-0A57h SHARE = NO SIZE = DWORD PORT = 0A70h-0A7Fh SHARE = NO SIZE = WORD INIT = IOPORT(4) LOC(7 2 1) 011 INIT = PORTADR(0A78h) 10000000 INIT = PORTADR(0A78h) 01100000 INIT = PORTADR(0A79h) 00000000 CHOICE = "4 = 1A18-1A23 & 1A30-1A3F" LINK PORT = 1A18h-1A1Fh SHARE = NO SIZE = DWORD PORT = 1A20h-1A23h SHARE = NO SIZE = DWORD PORT = 1A30h-1A3Fh SHARE = NO SIZE = WORD INIT = IOPORT(4) LOC(7 2 1) 100 INIT = PORTADR(1A38h) 10000000 INIT = PORTADR(1A38h) 01100000 INIT = PORTADR(1A39h) 00000000 CHOICE = "5 = 1A24-1A2F & 1A40-1A4F" LINK PORT = 1A28h-1A2Fh SHARE = NO SIZE = DWORD PORT = 1A24h-1A27h SHARE = NO SIZE = DWORD PORT = 1A40h-1A4Fh SHARE = NO SIZE = WORD INIT = IOPORT(4) LOC(7 2 1) 101 INIT = PORTADR(1A48h) 10000000 INIT = PORTADR(1A48h) 01100000 INIT = PORTADR(1A49h) 00000000 CHOICE = "6 = 1A50-1A53 & 1A58-1A6F" LINK PORT = 1A58h-1A5Fh SHARE = NO SIZE = DWORD PORT = 1A50h-1A53h SHARE = NO SIZE = DWORD PORT = 1A60h-1A6Fh SHARE = NO SIZE = WORD INIT = IOPORT(4) LOC(7 2 1) 110 INIT = PORTADR(1A68h) 10000000 INIT = PORTADR(1A68h) 01100000 INIT = PORTADR(1A69h) 00000000 CHOICE = "7 = 1A54-1A57 & 1A70-1A87" LINK PORT = 1A80h-1A87h SHARE = NO SIZE = DWORD PORT = 1A54h-1A57h SHARE = NO SIZE = DWORD PORT = 1A70h-1A7Fh SHARE = NO SIZE = WORD INIT = IOPORT(4) LOC(7 2 1) 111 INIT = PORTADR(1A78h) 10000000 INIT = PORTADR(1A78h) 01100000 INIT = PORTADR(1A79h) 00000000 SUBFUNCTION = "Adapter Data Rate" TYPE = "SPD" COMMENTS = "\nThis Token-Ring Network adapter can operate at two different data rates, 4 Mbps or 16 Mbps. You MUST set the adapter data rate to the same rate as the Token-Ring to which you are connecting the adapter." CHOICE = "16 Mbps" SUBTYPE = "16" LINK INIT = IOPORT(4) LOC(0) 1 CHOICE = "4 Mbps" SUBTYPE = "4" LINK INIT = IOPORT(4) LOC(0) 0 SUBFUNCTION = "FLASH RPL Address Location" COMMENTS = "\nThe FLASH RPL can be occupy one of 15 possible 8K areas, starting at C2000 through DE000." CHOICE = "FLASH RPL Disabled" LINK INIT = IOPORT(4) LOC(6 5 4 3) 0000 CHOICE = "C8000-C9FFF" LINK MEMORY = 8K ADDRESS = 0C8000h WRITABLE = YES SIZE = BYTE INIT = IOPORT(4) LOC(6 5 4 3) 0100 CHOICE = "CA000-CBFFF" LINK MEMORY = 8K ADDRESS = 0CA000h WRITABLE = YES SIZE = BYTE INIT = IOPORT(4) LOC(6 5 4 3) 0101 CHOICE = "CC000-CDFFF" LINK MEMORY = 8K ADDRESS = 0CC000h WRITABLE = YES SIZE = BYTE INIT = IOPORT(4) LOC(6 5 4 3) 0110 CHOICE = "CE000-CFFFF" LINK MEMORY = 8K ADDRESS = 0CE000h WRITABLE = YES SIZE = BYTE INIT = IOPORT(4) LOC(6 5 4 3) 0111 CHOICE = "D0000-D1FFF" LINK MEMORY = 8K ADDRESS = 0D0000h WRITABLE = YES SIZE = BYTE INIT = IOPORT(4) LOC(6 5 4 3) 1000 CHOICE = "D2000-D3FFF" LINK MEMORY = 8K ADDRESS = 0D2000h WRITABLE = YES SIZE = BYTE INIT = IOPORT(4) LOC(6 5 4 3) 1001 CHOICE = "D4000-D5FFF" LINK MEMORY = 8K ADDRESS = 0D4000h WRITABLE = YES SIZE = BYTE INIT = IOPORT(4) LOC(6 5 4 3) 1010 CHOICE = "D6000-D7FFF" LINK MEMORY = 8K ADDRESS = 0D6000h WRITABLE = YES SIZE = BYTE INIT = IOPORT(4) LOC(6 5 4 3) 1011 CHOICE = "D8000-D9FFF" LINK MEMORY = 8K ADDRESS = 0D8000h WRITABLE = YES SIZE = BYTE INIT = IOPORT(4) LOC(6 5 4 3) 1100 CHOICE = "DA000-DBFFF" LINK MEMORY = 8K ADDRESS = 0DA000h WRITABLE = YES SIZE = BYTE INIT = IOPORT(4) LOC(6 5 4 3) 1101 CHOICE = "DC000-DDFFF" LINK MEMORY = 8K ADDRESS = 0DC000h WRITABLE = YES SIZE = BYTE INIT = IOPORT(4) LOC(6 5 4 3) 1110 CHOICE = "DE000-DFFFF" LINK MEMORY = 8K ADDRESS = 0DE000h WRITABLE = YES SIZE = BYTE INIT = IOPORT(4) LOC(6 5 4 3) 1111 CHOICE = "C2000-C3FFF" LINK MEMORY = 8K ADDRESS = 0C2000h WRITABLE = YES SIZE = BYTE INIT = IOPORT(4) LOC(6 5 4 3) 0001 CHOICE = "C4000-C5FFF" LINK MEMORY = 8K ADDRESS = 0C4000h WRITABLE = YES SIZE = BYTE INIT = IOPORT(4) LOC(6 5 4 3) 0010 CHOICE = "C6000-C7FFF" LINK MEMORY = 8K ADDRESS = 0C6000h WRITABLE = YES SIZE = BYTE INIT = IOPORT(4) LOC(6 5 4 3) 0011 SUBFUNCTION = "Interrupt Level" TYPE = "INT" COMMENTS = "\nThis Token-Ring Network adapter uses one of eight interrupt levels: 3, 5, 7, 9, 10, 11, 14 or 15.\n The adapter uses level-triggered interrupts." CHOICE = "Interrupt 9" SUBTYPE = "9" LINK IRQ = 9 SHARE = YES TRIGGER = LEVEL INIT = IOPORT(2) LOC(2 1 0) 011 CHOICE = "Interrupt 3" SUBTYPE = "3" LINK IRQ = 3 SHARE = YES TRIGGER = LEVEL INIT = IOPORT(2) LOC(2 1 0) 000 CHOICE = "Interrupt 5" SUBTYPE = "5" LINK IRQ = 5 SHARE = YES TRIGGER = LEVEL INIT = IOPORT(2) LOC(2 1 0) 001 CHOICE = "Interrupt 10" SUBTYPE = "10" LINK IRQ = 10 SHARE = YES TRIGGER = LEVEL INIT = IOPORT(2) LOC(2 1 0) 100 CHOICE = "Interrupt 11" SUBTYPE = "11" LINK IRQ = 11 SHARE = YES TRIGGER = LEVEL INIT = IOPORT(2) LOC(2 1 0) 101 CHOICE = "Interrupt 14" SUBTYPE = "14" LINK IRQ = 14 SHARE = YES TRIGGER = LEVEL INIT = IOPORT(2) LOC(2 1 0) 110 CHOICE = "Interrupt 15" SUBTYPE = "15" LINK IRQ = 15 SHARE = YES TRIGGER = LEVEL INIT = IOPORT(2) LOC(2 1 0) 111 CHOICE = "Interrupt 7" SUBTYPE = "7" LINK IRQ = 7 SHARE = YES TRIGGER = LEVEL INIT = IOPORT(2) LOC(2 1 0) 010 SUBFUNCTION = "DMA Level" TYPE = "DMA" COMMENTS = "\nThis Token-Ring Network adapter can operate on one of six DMA channels: 0, 1, 3, 5, 6 or 7. The preferred DMA channel is 7.\n The DMA channel can be shared with other adapters of the same type.\n Additionally use of DMA can be disabled. This will force drivers to transfer data using 32 bit programmed I/O. Depending on the driver, this may reduce throughput." CHOICE = "DMA 7" SUBTYPE = "7" LINK DMA = 7 SHARE = "OLC1201" SIZE = DWORD TIMING = TYPEC INIT = IOPORT(2) LOC(5 4 3) 101 CHOICE = "DMA 6" SUBTYPE = "6" LINK DMA = 6 SHARE = "OLC1201" SIZE = DWORD TIMING = TYPEC INIT = IOPORT(2) LOC(5 4 3) 100 CHOICE = "DMA 5" SUBTYPE = "5" LINK DMA = 5 SHARE = "OLC1201" SIZE = DWORD TIMING = TYPEC INIT = IOPORT(2) LOC(5 4 3) 011 CHOICE = "DMA 3" SUBTYPE = "3" LINK DMA = 3 SHARE = "OLC1201" SIZE = DWORD TIMING = TYPEC INIT = IOPORT(2) LOC(5 4 3) 010 CHOICE = "DMA 1" SUBTYPE = "1" LINK DMA = 1 SHARE = "OLC1201" SIZE = DWORD TIMING = TYPEC INIT = IOPORT(2) LOC(5 4 3) 001 CHOICE = "DMA 0" SUBTYPE = "0" LINK DMA = 0 SHARE = "OLC1201" SIZE = DWORD TIMING = TYPEC INIT = IOPORT(2) LOC(5 4 3) 000 CHOICE = "No DMA" SUBTYPE = "-" LINK INIT = IOPORT(2) LOC(5 4 3) 110